THE BASIC PRINCIPLES OF DP50RB

The Basic Principles Of Dp50rb

The Basic Principles Of Dp50rb

Blog Article

one.two.2 Warning Labels Warning Labels Meaning Please diligently read this manual right before use gadget. The subsequent labels undoubtedly are a. Never put the gadget on the sloped floor. In any other case the offered when the system gadget may well slide, leading to particular injury or even the machine functions With all the cell malfunction.

The consumer isn't allowed to open up the covers and panel of the process, neither Observe: gadget disassemble is permitted. To ensure the method functionality and safety, only Mindray engineers or engineers licensed by Mindray can complete routine maintenance.

Be aware: On the check, the brightness adjustment arrives in advance of contrast. Following readjusting the observe’s contrast and brightness, regulate all preset and peripheral configurations.

Will not use any cables apart from the cables delivered Along with the system by Mindray. three. Make use of the cable delivered with this system to attach the printer. Other cables might bring about electric powered shock. Web page fifteen: Mechanical Security

Minimize off cable ties connecting the principle unit to the Display screen by diagonal chopping pliers, then pull out the corresponding cable plugs.

Articles System Test the battery periodically : a) Examine if battery can be charged Generally when energy-on: That The present potential is one hundred% or capacity increases just after a brief time signifies that the battery may be billed Commonly.

Webpage 145 Clean user interface Instruments: dry gentle fabric, gentle soapy h2o  Method:  Use dry smooth cloth to clean the surface of your system. When the procedure is dirty, moisten the comfortable cloth with delicate soapy drinking water and wipe off any stains. Use dry tender fabric to eliminate any humidity and permit all hard surfaces to entirely air-dry. Website page 146: Cleanse The Peripherals

Discover much better diagnostic data by prolonged look at with the anatomical framework on all convex probes.

Analyzing sufferers in these days’s demanding atmosphere requires impressive technological know-how that enables clinicians to make speedy and confident diagnoses. The versatility of the DP-50 expands your medical utility though helping to strengthen affected person care.

5.two.3 Geometric positioning precision Longitudinal geometric positioning precision  Examination Phase: Do changes as just how in tests the utmost depth. File the distance by 20mm Every phase to the longitudinal targets line using the measurement caliper; Select the value with the best error (to 20mm), work out the accuracy utilizing the formulation below The measurement caliper should be positioned at the higher edge of the goal, Observe:... Webpage 79 Transverse geometric positioning accuracy  Examination Stage: Cover the scan area in the phantom with drinking water or pair gel, Carefully Speak to the probe With all the scan surface area Alter the depth, creating the transverse targets for being displayed in the graphic. Adjust the main target point being posited beside the transverse targets (the conventional just isn't very clear) Regulate parameters like attain, TGC, making Just about every transverse targets to be Evidently exhibited. Website page 80 5.five.2.four Blackout Space Exam Step: Include the scan surface of the phantom with water or pair gel, gently Make contact with the probe Together with the scan surface area Adjust the depth at a reduced value, and established the focus at the nearest destination to the scan surface. Lower the worth of parameters like AP, Achieve till the qualifications sounds just could be witnessed. Page 81: Software Update And Upkeep

The DP-50 Professional is surely an progressive, higher-overall performance Ultrasound Process engineered that can assist you get the insights you would like. The Technique’s potent motor and significant-velocity processing offer remarkable image excellent and an entire info management Remedy.

.. Page 161 The indicator to the printer Errors take place if the adapter turns orange, as well as printing printer adapter operates. Disconnect and join the fails. ability adapter, power within the printer adapter once again, and confirm whether or not the printing is normal soon after 1 moment. Web site Dp50rb 163: Electrical Basic safety Inspection

Cookies are very important to the correct functioning of the website. To improve your experience, we use cookies to keep in mind log-in specifics and supply secure log-in, gather studies to improve web site operation, and supply articles tailor-made for your passions.

Your Resource for deeper biopsy: enabling adjustments to the scan line to get greater visibility from the needle, nerves and small vessels, guaranteeing the continuity of all facts.

Take note: Guantee that you may pull out and force to the IO board sockets vertically when pulling out and assembling the IO board assembly over the place from the cope with. Remove panhead screws with washers M3X6 (4) used to safe the IO board, and afterwards you can acquire out the IO board. Web site 116 Eliminate panhead screws with washers (two M3X6) which can be fastened on the most crucial device, take out the higher baffle and then pull out two cables connecting the key board to the power module assembly.